SC-01 Strain cable sensor

Gallery


3D Visualisation



Loading file
  • Fullscreen
  • Wireframe
  • Zoom In
  • Zoom Out
  • Rotation
  • Screenshot
  • Help

Controls

×
  • Rotate with the left mouse button.
  • Zoom with the scroll button.
  • Adjust camera position with the right mouse button.
  • Double-click to enter the fullscreen mode.
  • On mobile devices swipe to rotate.
  • On mobile devices pinch two fingers together or apart to adjust zoom.
  • On mobile devices 3 finger horizontal swipe performs panning.
  • On mobile devices 3 finger horizontal swipe performs panning.


Ask a question

Documents



DatasheetDrawingInstallation
Manual
Standard WL configurationPackagingCleaning and Mating ManualOrdering codesCalibration sheet3D file
.STEP
Download all documents

Open

Open
soon…
Open
soon…
Open
soon…
Open

e-mail
soon…

Characteristics



  • Long gauge strain sensor with 30cm to 10mtr measuring base (gauge length).
  • SC-01 is measuring strain between its anchoring brackets and is therefore immune to local defects or inhomogeneity.
  • Integrated temperature compensation.
  • SC-01 can be connected in series configuration.

Application



  • Strain profile in concrete or metal structures (ceiling pillars, roofs, walls)
  • Crack monitoring
  • Deformations
  • Borehole deformation (embedded or grouted)

Product specification


Performance properties
Strain range
±5000μɛ
Accuracy (guaranteed)1)
<0.35% FS3)

Accuracy (typical)1)
<0.18% FS3)

Precision (guaranteed)2)
<0.15% FS3)

Precision (typical)2)
<0.10% FS3)
Temperature compensation Integrated
Temperature accuracy1)
<1°C
Temperature precision2)
±0.3°C
Temperature resolution
0.05°C
Temperature sensitivity
28pm/°C
Strain sensitivity
∽1.35pm/µɛ
Operating Temperature range -20°C to +60°C
Ingress Protection rating
IP 67
Physical properties
Housing material
Stainless steel SS316L and polyamide
Anchoring distance
Adjustable parameter

Dimensions (without cable)4)
Ø12 mm x L mm [Washer Ø24 mm]

Weight (without cable)
450g

Cable type
3mm Dyneema reinforced cable
Cable length5) 1mtr
Cable Bend Radius (dynamic)
40mm
Cable Bend Radius (static)
30mm
Connector type6)
FC/APC

Mounting method Mounting brackets
Packaging Cardboard box – dimensions depending on the final configuration.
Quality Statement SC-01 sensor is compliant with IEC 61757-1-1:2020, IEC 61757-2-1:2021 and IEC 61757:2018
All sensors are 100% tested and calibrated at SYLEX.
Sensor is manufactured according to ISO 9001:2015 and ISO 14001:2015

Notes:

  • 1) Accuracy is established for each individual sensor under laboratory conditions and it includes hysteresis, non-linearity and repeatability of the sensor.
  • 2) Precision is established on a batch basis and it includes hysteresis, non-linearity, repeatability and reproducibility of the sensor.
  • 3) FS: full scale range
  • 4) For further dimensions details see the product drawing
  • 5) Cable length is extendable on request
  • 6) Other connector types available on request