SAT-01 Single Axis Tiltmeter
3D Visualisation
![Loading file](https://test.sylex.sk/wp-content/plugins/woo-3d-viewer/images/ajax-loader.gif)
Controls
×- Rotate with the left mouse button.
- Zoom with the scroll button.
- Adjust camera position with the right mouse button.
- Double-click to enter the fullscreen mode.
- On mobile devices swipe to rotate.
- On mobile devices pinch two fingers together or apart to adjust zoom.
- On mobile devices 3 finger horizontal swipe performs panning.
- On mobile devices 3 finger horizontal swipe performs panning.
Characteristics
- Fiber Bragg Grating based single-axis tilt meter, specifically designed to measure long term angular variations of large structures.
- The highly sensitive fiber optic tiltmeter has an angular measurement range of 10 and is temperature compensated to ensure high stability.
Application
- Tilt changes detection
- Can be mounted on different surfaces including walls, etc.
Benefits
- Robust stainless steel
- Double-ended
- Temperature-compensated
- Large angular range
- High sensitivity
Related products
Product specification
Performance properties |
Measurement range
|
-5deg. to +5deg.
|
|
Accuracy (typical) 1)
|
1% F.S. 2) | ||
Resolution
|
8,33.10-6deg. | ||
Sensitivity
|
550 pm/deg. ± 50 pm/deg. | ||
Response time
|
<3 sec.
|
||
Operating Temperature range |
-20°C to +60°C
|
||
Ingress Protection rating |
IP 67
|
||
Physical properties |
Housing material
|
1.4404 (SS 316L)
|
|
Anchoring bolt
|
M5 / 5Nm | ||
Dimensions (without cable)3)
|
75 x 32 x 120 mm | ||
Weight (without cable)
|
1500g | ||
Cable type
|
3mm reinforced cable
|
||
Cable length4) | 1mtr | ||
Cable Bend Radius (dynamic) |
40mm
|
||
Cable Bend Radius (static) |
30mm
|
||
Connector type5)
|
FC/APC | ||
Mounting method | Screws, glue, or spot welding | ||
Packaging | Cardboard box – dimensions depending on the final configuration. | ||
Quality Statement | The sensor is compliant with IEC 61757:2018. All sensors are 100% tested and calibrated at SYLEX. The sensor is manufactured according to ISO 9001:2015 and ISO 14001:2015 |
Notes:
- 1) Accuracy is established for each sensor under laboratory conditions and it includes hysteresis, non-linearity, and
repeatability of the sensor - 2) FS: full-scale range
- 3) For further dimensions details see the product drawing
- 4) Cable length is extendable on request