TPA-01 Temperature array sensor

Gallery


3D Visualisation



Loading file
  • Fullscreen
  • Wireframe
  • Zoom In
  • Zoom Out
  • Rotation
  • Screenshot
  • Help

Controls

×
  • Rotate with the left mouse button.
  • Zoom with the scroll button.
  • Adjust camera position with the right mouse button.
  • Double-click to enter the fullscreen mode.
  • On mobile devices swipe to rotate.
  • On mobile devices pinch two fingers together or apart to adjust zoom.
  • On mobile devices 3 finger horizontal swipe performs panning.
  • On mobile devices 3 finger horizontal swipe performs panning.


Ask a question

Documents



DatasheetDrawingInstallation
Manual
Standard WL configurationPackagingCleaning and Mating ManualOrdering codesCalibration sheet3D file
.STEP
Download all documents

Open

Open
soon…soon…soon…
Open
soon…
Open

e-mail
soon…

Characteristics



  • TPA-01 is multi-segment temperature compensating chain.
  • TPA-01 can be mounting to the surface parallel to fiber optic strain gauges.
  • TPA-01 is accurate sensor with high temperature measuring range.
  • TPA-01 can be connected in series configuration with other sensors by connector or splice connection.

Application



  • Temperature measurement applicable in different fields.
  • Temperature compensation of strain sensors.

Product specification


Performance properties
Temperature range
-20°C up to +80°C
Temperature accuracy
1°C

Temperature accuracy (typical)1)
<1°C

Temperature precision
±0,3°C

Temperature precision (typical)2)
±0,2°C
Ingress Protection rating IP 67
Physical properties
Housing material
Glass
Number of measuring sections3) Up to 20
Dimensions (without cable)4) Ø 2mm x 30mm
Weight (without cable)5) 50g
Cable type 900μm PVDF tubing (yellow)
Cable length6) 1mtr
Cable Bend Radius (dynamic) 30mm
Cable Bend Radius (static) 15mm
Connector type7) FC/APC
Mounting method Surface mounting
Packaging Cardboard box with dimensions: 370x290x45mm
Quality Statement TPA-01 sensor is compliant with IEC 61757:2018 and IEC 61757-2-1:2021.
All sensors are 100% tested and calibrated at SYLEX.
Sensor is manufactured according to ISO 9001:2008 and ISO 14001:2004

Notes:

  • 1) Accuracy is established for each individual sensor under laboratory conditions and it includes hysteresis, non-linearity and repeatability of the sensor.
  • 2) Precision is established on a batch basis and it includes hysteresis, non-linearity, repeatability and reproducibility of the sensor.
  • 3) Number of measuring sections depends on customer’s requirement
  • 4) For further dimensions details see the product drawing
  • 5) Valid for 6mtr long sensor with 6 measuring sections
  • 6) Cable length is extendable on request
  • 7) Other connector types available on request