STS-04 Surface high-temperature sensor

3D Visualisation



Loading file
  • Fullscreen
  • Wireframe
  • Zoom In
  • Zoom Out
  • Rotation
  • Screenshot
  • Help

Controls

×
  • Rotate with the left mouse button.
  • Zoom with the scroll button.
  • Adjust camera position with the right mouse button.
  • Double-click to enter the fullscreen mode.
  • On mobile devices swipe to rotate.
  • On mobile devices pinch two fingers together or apart to adjust zoom.
  • On mobile devices 3 finger horizontal swipe performs panning.
  • On mobile devices 3 finger horizontal swipe performs panning.


Ask a question

Documents



DatasheetDrawingInstallation
Manual
Standard WL configurationPackagingCleaning and Mating ManualOrdering codesCalibration sheet3D file
.STEP
Download all documents

Open

Open
soon…
Open
soon…
Open
soon…
Open

e-mail
soon…

Characteristics



  • STS-04 has high temperature measuring range up to 250°C.
  • STS-04 has small dimensions.

Application



  • Surface temperature measurement
  • Chemical and oil & gas applications

Product specification


Performance properties
Temperature range1)
-50°C up to +250°C
Temperature accuracy
1% FS4)

Temperature accuracy (typical)2)
0.8% FS4)

Temperature precision
±0,30% FS4)

Temperature precision (typical)3)
±0,20% FS4)
Temperature resolution 0,1°C
Temperature sensitivity 11 pm/°C
Ingress Protection rating IP 65
Physical properties
Housing material
Stainless steel SS316L and CW004A Cu-ETP
Dimensions (without cable)5) Ø34mm x 9.5mm
Weight (without cable) 45g
Cable type 3mm Stainless steel tubing / 3mm Dyneema tubing
Cable length6) 2mtr
Cable Bend Radius (dynamic) 30mm
Cable Bend Radius (static) 15mm
Connector type7) FC/APC
Mounting method Direct surface mounting
Packaging Cardboard box with dimensions: 370x290x45mm
Quality Statement STS-04 sensor is compliant with IEC 61757:2018 and IEC 61757-2-1:2021.
All sensors are 100% tested and calibrated at SYLEX.
Sensor is manufactured according to ISO 9001:2008 and ISO 14001:2004

Notes:

  • 1) Temperature resistance up to 300°C. Calibration range to be agreed with client based on the project requirements.
  • 2) Accuracy is established for each individual sensor under laboratory conditions and it includes hysteresis, non-linearity, and repeatability of the sensor.
  • 3) Precision is established on a batch basis and it includes hysteresis, non-linearity, repeatability and reproducibility of the sensor.
  • 4) FS: full scale range
  • 5) For further dimensions details see the product drawing.
  • 6) Cable length is extendable on request.
  • 7) Other connector types available on request.