MTP – LC 12-fiber Duralino fanout – 900um
- The version of our MTP to LC 900um fanout allows you to split the parallel 12-fiber link into individual 900um connections. The round cable, combined with the compact and robust design of the Duralino fanout, allows rapid deployment of high density patching in SAN and LAN DataCenter environments, where additional cable protection is necessary.
- MTP® PRO connector optional
Product specifications
Temperature range
|
Indoor controlled environment (-10°C/+60°C) | ||
Cable parameters |
Jacket material
|
LSZH
|
|
Cable construction
|
Round jacket cable | ||
Outer diameter
|
3.0mm | ||
Fiber count
|
12 | ||
Fiber type
|
SM OS2 or MMF OM3/OM4/OM5
|
||
Temperature range | Operation: -10°C to +70°C | ||
Storage: -25°C to +70°C | |||
Installation: -5°C to +50°C
|
|||
CPR
|
Cca-s1a, d1, a2
|
||
Connector parameters | MTP/MTP PRO SM / MM | LC SM / LC MM | |
Compliance
|
US CONEC standard
|
Telcordia GR-326 | |
Colour of housing
|
SM – Green (APC)
MM – Aqua/Magenta/Lime Green
|
SM – Blue (PC)/Green (APC) MM – Aqua/Magenta/Lime Green |
|
Colour of boot
|
Black | Green (APC)/White | |
Polish
|
Angled (APC) / Flat (PC) | Angled (APC) / Flat (PC) | |
Insertion Loss
(acc. IEC 61300-3-4 method B)
|
<0,35dB
(@1310/1550nm / @850/1300nm)
|
<0,25dB (@1310/1550nm / @850/1300nm) |
|
Return Loss
(acc. IEC 61300-3-6)
|
>50dB(APC) / >20dB
(@1310/1550nm / @850/1300nm)
|
>50dB(UPC)/>60dB(APC) / >30dB (@1310/1550nm / @850/1300nm) |
|
Identification | Traceability label with unique serial number on both ends of cable assembly. | ||
Packaging |
Each assembly in sealed PE bag, bulk pack in cardboard box. Longer lengths coiled on cardboard/wooden reel.
|
Documents
Partnumbers/Ordering codes
Description
|
Partnumber/Ordering code
|
1x12f MTP(F) to 12xLC/APC 12-fiber OS2 Duralino fanout, 900um | F129-FA9-xxx |
1x12f MTP(F) to 12xLC/PC 12-fiber OS2 Duralino fanout, 900um | F129-FL9-xxx |
1x12f MTP(F) to 12xLC/PC 12-fiber OM3 Duralino fanout, 900um | F123-FL9-xxx |
1x12f MTP(F) to 12xLC/PC 12-fiber OM4 Duralino fanout, 900um | F124-FL9-xxx |
1x12f MTP(F) to 12xLC/PC 12-fiber OM5 Duralino fanout, 900um | F125-FL9-xxx |
1x12f MTP(M) to 12xLC/APC 12-fiber OS2 Duralino fanout, 900um | F129-MA9-xxx |
1x12f MTP(M) to 12xLC/PC 12-fiber OS2 Duralino fanout, 900um | F129-ML9-xxx |
1x12f MTP(M) to 12xLC/PC 12-fiber OM3 Duralino fanout, 900um | F123-ML9-xxx |
1x12f MTP(M) to 12xLC/PC 12-fiber OM4 Duralino fanout, 900um | F124-ML9-xxx |
1x12f MTP(M) to 12xLC/PC 12-fiber OM5 Duralino fanout, 900um | F125-ML9-xxx |
1x12f MTP(F) PRO to 12xLC/APC 12-fiber OS2 Duralino fanout, 900um | F129-JA9-xxx |
1x12f MTP(F) PRO to 12xLC/PC 12-fiber OS2 Duralino fanout, 900um | F129-JL9-xxx |
1x12f MTP(F) PRO to 12xLC/PC 12-fiber OM3 Duralino fanout, 900um | F123-JL9-xxx |
1x12f MTP(F) PRO to 12xLC/PC 12-fiber OM4 Duralino fanout, 900um | F124-JL9-xxx |
1x12f MTP(F) PRO to 12xLC/PC 12-fiber OM5 Duralino fanout, 900um | F125-JL9-xxx |
1x12f MTP(M) PRO to 12xLC/APC 12-fiber OS2 Duralino fanout, 900um | F129-PA9-xxx |
1x12f MTP(M) PRO to 12xLC/PC 12-fiber OS2 Duralino fanout, 900um | F129-PL9-xxx |
1x12f MTP(M) PRO to 12xLC/PC 12-fiber OM3 Duralino fanout, 900um | F123-PL9-xxx |
1x12f MTP(M) PRO to 12xLC/PC 12-fiber OM4 Duralino fanout, 900um | F124-PL9-xxx |
1x12f MTP(M) PRO to 12xLC/PC 12-fiber OM5 Duralino fanout, 900um | F125-PL9-xxx |
1x12f MTP(F) to 12xLC/APC 12-fiber OS2 Duralino fanout with grommet, 900um | H129-FA9-xxx |
1x12f MTP(F) to 12xLC/PC 12-fiber OS2 Duralino fanout with grommet, 900um | H129-FL9-xxx |
1x12f MTP(F) to 12xLC/PC 12-fiber OM3 Duralino fanout with grommet, 900um | H123-FL9-xxx |
1x12f MTP(F) to 12xLC/PC 12-fiber OM4 Duralino fanout with grommet, 900um | H124-FL9-xxx |
1x12f MTP(F) to 12xLC/PC 12-fiber OM5 Duralino fanout with grommet, 900um | H125-FL9-xxx |
1x12f MTP(M) to 12xLC/APC 12-fiber OS2 Duralino fanout with grommet, 900um | H129-MA9-xxx |
1x12f MTP(M) to 12xLC/PC 12-fiber OS2 Duralino fanout with grommet, 900um | H129-ML9-xxx |
1x12f MTP(M) to 12xLC/PC 12-fiber OM3 Duralino fanout with grommet, 900um | H123-ML9-xxx |
1x12f MTP(M) to 12xLC/PC 12-fiber OM4 Duralino fanout with grommet, 900um | H124-ML9-xxx |
1x12f MTP(M) to 12xLC/PC 12-fiber OM5 Duralino fanout with grommet, 900um | H125-ML9-xxx |
1x12f MTP(F) PRO to 12xLC/APC 12-fiber OS2 Duralino fanout with grommet, 900um | H129-JA9-xxx |
1x12f MTP(F) PRO to 12xLC/PC 12-fiber OS2 Duralino fanout with grommet, 900um | H129-JL9-xxx |
1x12f MTP(F) PRO to 12xLC/PC 12-fiber OM3 Duralino fanout with grommet, 900um | H123-JL9-xxx |
1x12f MTP(F) PRO to 12xLC/PC 12-fiber OM4 Duralino fanout with grommet, 900um | H124-JL9-xxx |
1x12f MTP(F) PRO to 12xLC/PC 12-fiber OM5 Duralino fanout with grommet, 900um | H125-JL9-xxx |
1x12f MTP(M) PRO to 12xLC/APC 12-fiber OS2 Duralino fanout with grommet, 900um | H129-PA9-xxx |
1x12f MTP(M) PRO to 12xLC/PC 12-fiber OS2 Duralino fanout with grommet, 900um | H129-PL9-xxx |
1x12f MTP(M) PRO to 12xLC/PC 12-fiber OM3 Duralino fanout with grommet, 900um | H123-PL9-xxx |
1x12f MTP(M) PRO to 12xLC/PC 12-fiber OM4 Duralino fanout with grommet, 900um | H124-PL9-xxx |
1x12f MTP(M) PRO to 12xLC/PC 12-fiber OM5 Duralino fanout with grommet, 900um | H125-PL9-xxx |
Related products
-
MTP – LC 12-fiber Duralino fanout – Duplex
The version of our MTP to LC duplex fanout allows you to split the parallel 12-fiber link into individual duplex connections. The round cable, combined with the compact and robust design of the Duralino fanout, allows rapid deployment of high density patching in SAN and LAN DataCenter environments, where additional cable protection is necessary.READ MORE -
MTP – LC 12-fiber Duralino fanout – Simplex
The version of our MTP to LC simplex fanout allows you to split the parallel 12-fiber link into individual simplex connections. The round cable, combined with the compact and robust design of the Duralino fanout, allows rapid deployment of high density patching in SAN and LAN DataCenter environments, where additional cable protection is necessary.READ MORE